General Measures
- Discontinue volatile anesthetics
- Change Anesthesia Machine and circuit
- Hyperventilate 100% FIO2 high Flows
- Consider Invasive monitors
- Institute cooling measures:
- Gastric lavage
- Cooling blanket
- Cold IV solutions
- Monitor UOP, K+,Ca++, ABG,ETCO2, pt,ptt
|